Debugging ADC with no HW Trigger Present

$
0
0
Hi Christine,

Yes, you can start conversions by software, e.g. for verify an ADC configuration without a proper HW Trigger. This is often the case when you are debugging to find the root source of ADC conversion issues. In the case of AURIX™ TC2XX, for Scan and
Background Scan, each request source has a LDEV (GxASMR.LDEV=1 and BRSMR.LDEV=1) bit that can load the ADC request source. And for queues, there is a TREV field (GxQMRy.TREV=1) that can be used to load this type of request source.

Best regards,
Mr. AURIX™