Quantcast
Channel: Infineon Forums
Viewing all articles
Browse latest Browse all 9892

VADC Sample and Conversion time longer than defined?

$
0
0
Hello,

I am trying to use the ADC of XMC4800 as fast as possible.
So I took the DAVE APP "ADC_MEASUREMENT" and defined sample time as 55.6nsec which results in a total conversion time of 458.333nsec.
I set "Start conversion after initialization" so that I get a first conversion. I set up a "End of measurement interrup" in which I call "ADC_MEASUREMENT_StartConversion" at the end so that it starts the next conversion.

What I now see with my oscilloscope is that I get a conversion time of around 2microsec instead of 458

Code:

void ADC_INT()
{
        DEBUG_ON;                                                                                    // set Digital IO

        DEBUG_OFF;                                                                                  // reset Digital IO
        ADC_MEASUREMENT_StartConversion(&ADC_MEASUREMENT_0);

}

The time in the interrupt routine takes about 1microsec (measured on oscilloscope with the digital IO).

Does anyone know why it takes so long? Did I miss some configurations (that is my assumption)?
Should I use other APPs?
Should I use a DMA transfer so that I can save time with not going into the interrupt routine? Nevertheless, somehow I have to read and process the ADC data. Actually I wanted to use "ADC_MEASUREMENT_GetResult()" in the interrupt to read the values, but this consume even more time for the interrupt handling and conversion time.....

Hopefully there is someone who had similar problems.

Appreciate your help!