Quantcast
Channel: Infineon Forums
Browsing all 9892 articles
Browse latest View live

CCU80 SR interrupt issue

Dear All, The part number is : XMC1300 series, XMC1302-Q040X0064 I have configured CCU8_CCU80 slice for PWM generation. As per the configuration SR0 is selected for Interrupt and is working fine, ISR...

View Article


XMC1300 VADC channels with different groups triggered by CCU8

Dear All, The part number is : XMC1300 series, XMC1302-Q040X0064 I have configured CCU8_CCU80 slice for PWM generation. As per the configuration SR0 is selected for Interrupt and is working fine, ISR...

View Article


CCU8 ISR issue with Service Request Line

Dear All, The part number is : XMC1300 series, XMC1302-Q040X0064 I have configured CCU8_CCU80 slice for PWM generation. As per the configuration SR0 is selected for Interrupt and is working fine, ISR...

View Article

CCU8 interrupt issues based on service request line

Dear All, The part number is : XMC1300 series, XMC1302-Q040X0064 I have configured CCU8_CCU80 slice for PWM generation. As per the configuration SR0 is selected for Interrupt and is working fine, ISR...

View Article

ADC Parallel Sampling too slow?

Hey there, I started µC-programming a few weeks ago and as a newbie I am very greatful for the DAVE-APPS ;) It makes it much more easier for me. I've got a XMC4200Q48-Hexagon-Kit and I want to do...

View Article


XMC4800 EtherCAT Process Data Watchdog event

Hello team, I am trying to catch the Process Data (PD) timeout event when connection lost. When I unplug EtherCAT cable, I can see updating of 'Watchdog Status Process Data register (WD_STAT_PDATA)'...

View Article

Impossible to set BMI

Hi Jesus. How can i enable JTAG or DAP interface in the TC1724 32-bit Tricor?my tc1724 is new and all setting is in default. i can connect in ASC Bootloader mode by memtool to device but in JTAG ot DAP...

View Article

Dave4 BLDC hall sensor base with SPWM/SPWM example

Hi, I am new to BLDC. I have BLDC project for fan application, customer request using sinusoidal drive and must be sensor base. I just found BLDC scalar Hall and FOC code examples on Dave 4. Scalar...

View Article


Teste infineon tc1797

Hi Giga. I am working on TriCor mpu too. but TC1724N. what the test you want?do you have the TriBoard TC1797?

View Article


DAP miniwiggler on Aurix Kit TC297

Hi Divya. this error is for because the DAS cannot identify your Kit still.can you try connect to your kit in ASC Bootloader mode? may be your configuration is wrong??

View Article

Ethernet connection to External Host

I was working with the Ethernet demo example code that comes with the Infineon framework. This example has the triboard running in loopback mode and sending and receiving packets without actually...

View Article

XMC4500 Flash protection in practice?!

Good day, I have read "XMC4500 Reference Manual" chapter 8.4.8 Flash Protection, but it is still unclear for me how it should be realized? Say, I choose to set up "Flash Read Protection", using option:...

View Article

DAVE4 - Synchronous ADC - which APP?

I know this is a very late answer, but maybe there is someone out there having the same question. Meanwhile there is a APP for sync. Conversion and I'm really grateful for that :D It's named...

View Article


Image may be NSFW.
Clik here to view.

Voltage Reference Question

Hello all. Thanks for taking up your time to read my post. I'm new to regulators and references and I'm trying to update this old circuit that uses an op-amp as a 2.5V voltage reference by possibly...

View Article

Image may be NSFW.
Clik here to view.

XMC1300 CCU4 Use for puls generation AND trigger for ADC

Hi, I would like to produce the following pulse sequence: _|_|_|____|_|_|____|_|_|____...|_|_|______________ ______________|_|_|____|_|_|____ tp = 2µs t1 = 50µs t2 = 370µs t3 = 2000µs After each pulse...

View Article


TwinCAT Run Configuration XMC4800

Hi, I followed the example of Infineon on how to setup the XMC4800 as a EtherCAT Slave. In TwinCAT I configured one special CPU just for TwinCAT to make the application Realtime-capable. In the Config...

View Article

Programming SAK-TC1782 use command line

Which prommang and Software Can Program SAK-TC1782 use command line

View Article


CAN Bus communication on an XMC 4500

Hi, I am facing a problem with CAN interface with XMC4500. I am using CAN app in DAVE. I am receiving the packet but want to access the data bytes received. Couldn't find the right parameter in the...

View Article

Quadrature Decoder IRQ XMC1300

Hi Jesus, the interrupt with the index signal is not running at the moment. i got an incremental encoder with TTL signals, i attached a osciloscope picture with A, B and index signals. For now i only...

View Article

XMCLib CAN config

HI Kaur, for this you can take a look at the MULTICAN_CONFIG_EXAMPLE_XMC47 (http://www.infineon.com/cms/en/produ...downloads.html), more precisely to "CAN_IRQHandler" function which reads-out the data...

View Article
Browsing all 9892 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>